Skip to content
Contact us
Literature

Link

Integrated units with gas heat pumps and gas chillers

For heating, cooling and DHW production.

Benefits

  • Factory-assembled for faster installation.
    Robur assembles the selected units at the factory and ships them as a single package, reducing on-site assembly work and installation time.
  • Capacity matched to the project.
    Configure each Link assembly with up to six units to match the building’s load. Choose RTA with GAHP A Plus heat pumps for heating, RTAR with reversible GAHP AR Plus heat pumps for heating and cooling, or RTCF with ACF chillers for cooling.
  • Simplified gas and water connections.
    Shared gas and water connection points simplify the piping needed to connect the assembly to the building system.
  • Centralized cascade control.
    A single Robur controller stages the units as demand changes, bringing additional capacity online when needed.
  • Stainless steel frame and water header.
    A common stainless steel frame supports the units, and an integrated stainless steel water header simplifies on-site piping.

Versions

  • RTA – Heating.
    Factory-assembled system with up to 6 Robur GAHP A Plus air-to-water gas absorption heat pumps for hydronic heating.
  • RTAR – Heating and cooling.
    Factory-assembled system with up to 6 Robur GAHP AR Plus reversible air-to-water gas absorption heat pumps. The system supplies hot water for heating or chilled water for cooling.
  • RTCF – Cooling.
    Factory-assembled system with up to 6 Robur ACF gas absorption chillers for hydronic cooling.

Applications

  • Hydronic heating and cooling for commercial buildings, including offices, retail spaces, and hotels.
  • Space heating and cooling for industrial facilities such as factories, warehouses, and logistics centers.
  • Central heating and cooling for schools, universities, and other public buildings.
  • Central hydronic systems for multifamily residential buildings.
  • Industrial process cooling, with the ACF chiller selected to match the required fluid temperature.

Technical table

RTA Series

PERFORMANCE RATINGS - HEATING (1) RTA 00-240 RTA 00-360 RTA 00-480 RTA 00-600
Heating capacity (2) Btu/h 247,000 370,500 494,000 617,500
Gas input Btu/h 191,000 286,500 382,000 477,500
Ambient operating temperature maximum °F 113
minimum °F -20
Hot water temperature maximum outlet (to hydronic system) °F 140
minimum inlet (to unit) °F 122
Hot water flow nominal GPM 27.2 40.8 54.4 27.2
Internal pressure drop at nominal hot water flow psig 4.3
ELECTRICAL RATINGS (3)
Required voltage, 60 Hz, single phase (4) V 208 - 230
Operating consumption (3) kW 1.8 2.7 3.6 4.5
PHYSICAL DATA (1)
Operating weight pounds 2,086 3,144 4,027 5,242
Hot Water Supply and Return FPT

2"

Gas Inlet Connections FPT

11/4"

Dimensions width inches

49

length inches 102 153 204

255

height inches

53 1/4

 

Controllers

Direct Digital Control (DDC)

Direct Digital Control (DDC)

Robur Box 200

Robur Box 200

Literature

A new level of energy efficiency for a major retail chain in northern Italy

A new level of energy efficiency for a major retail chain in northern Italy
  • Customer Carrefour
  • Products GAHP A Plus, ACF ST, GAHP AR Plus, Link
  • Application Commercial

Gas air conditioning for the offices of a large company

Gas air conditioning for the offices of a large company
  • Customer New York Department of Sanitation
  • Products ACF ST, Link
  • Application Public buildings

Gas chillers for the controlled seasoning of cheese

Gas chillers for the controlled seasoning of cheese
  • Customer Greci Formaggi
  • Products ACF TK, Link
  • Application Industrial

Gas chillers and heat pumps for air conditioning in a company

Gas chillers and heat pumps for air conditioning in a company
  • Customer Northeast Electronics Corporation
  • Products GAHP AR Plus, ACF TK, Link
  • Application Industrial

Very low noise with the gas chiller-heaters in a medical centre

Very low noise with the gas chiller-heaters in a medical centre
  • Customer Kings Harbor Multicare Center
  • Products Link
  • Application Commercial

Gas cooling on the island of Martha’s Vineyard

Gas cooling on the island of Martha’s Vineyard
  • Customer Chappaquiddick Bay
  • Products ACF ST, Link
  • Application Commercial

25,000 sq. ft. building air-conditioned by gas chiller and gas heat pumps

25,000 sq. ft. building air-conditioned by gas chiller and gas heat pumps
  • Customer Demsey Manufacturing Co., Inc
  • Products ACF ST, GAHP AR Plus, Link
  • Application Industrial

Modular system adjustable according to the needs of the various structures of the hotel group

Modular system adjustable according to the needs of the various structures of the hotel group
  • Customer LO.AN Group Hotels
  • Products ACF ST, Link
  • Application Commercial

One-eighth of the electricity, with unchanged cooling capacity for the haute cuisine academy

One-eighth of the electricity, with unchanged cooling capacity for the haute cuisine academy
  • Customer Boscolo Etoilé Academy
  • Products ACF ST, GAHP AR Plus, ACF HR, Link
  • Application Commercial

24% savings, reduction of polluting emissions and high efficiency all year round

24% savings, reduction of polluting emissions and high efficiency all year round
  • Customer Municipality in Milan
  • Products GAHP AR Plus, Link
  • Application Commercial

Energy efficency improvement of 1500 square meters without solar panels

Energy efficency improvement of 1500 square meters without solar panels
  • Customer Guesthouse of Certosa di Pavia
  • Products GAHP AR Plus, Link
  • Application Commercial