GA ACF 60 Hz

Gas-powered absorption chiller

Low-energy consumption cooling.

Benefits

  • Reduce cooling costs, including electricity consumption. HFC-free gas absorption chillers ensure continuous operation and low maintenance thanks to compressor-free technology.
  • Cooling with extremely low electricity consumption.
  • Available in Natural Gas or Propane versions.
  • Single-phase power supply. Only 0.75 kW electrical power consumption for a 5 TON modular chiller.
  • Proven savings: up to 86% less electricity consumption. Peak electrical demand is reduced to less than 0.75 kW, eliminating the need for large and costly back-up generators.
  • Uses a natural refrigerant: ODP = 0 | GWP = 0 | HFC-free | PFAS-free.

Versions

TK Version

Industrial & Commercial applications requiring heavy use on a year round basis, even at ambient temperatures down to 10 °F | -12 °C.

HT Version

Any application in severe climates with design temperatures up to 131 °F | 55 °C.

LB Version

Medium-Temperature refrigeration applications with cold water production down to 14 °F | -10 °C.

Technical table

Cooling mode

  ACF 60-00 ST ACF 60-00 TK ACF 60-00 HT ACF 60-00 LB
Cooling capacity nominal kBtu/h 60.5(1) 58.4(1) 45.4(2)
kW 17.7 17.1 13.3
Gas input (HHV) nominal kBtu/h 94.9
kW 27.8
COP/GUE nominal % 71 68 53
Cold water outlet temperature minumum ° F 37.4 41 14
° C 3 5 -10
Cold water inlet temperature maximum ° F 113
° C 45
Ambient operating temperature maximum ° F 120 131 120
° C 49 55 49
minimum ° F 32 10 32 10
° C 0 -12 0 -12

 

Electrical specifications

Power supply voltage V 208-230
type -- single-phase
frequency Hz 60
Total electrical operating consumption (3) unit only kW 0.75

 

General information

Cooling fluid ammonia R717
water H2O
GWP Global Warming Potential 0
ODP Ozone Depletion Potential 0

 

(1) Cooling capacity at standard conditions of 95 °F | 35 °C ambient temperature. Chilled water outlet temperature 45 °F | 7 °C, inlet 55 °F | 12 °C.
(2) Cooling capacity at standard conditions of 95 °F | 35 °C ambient temperature. Chilled water outlet temperature 23 °F | -5 °C (with 40% ethylene glycol), inlet 32 °F | 0 °C.
(3) ±10% according to the power supply voltage and tolerance on electrical motors consumption. Measured at outdoor temperature of 86 °F | 30 °C.