GA ACF HR 60 Hz

Gas absorption chiller-heater with heat recovery

Cooling and simultaneous production of free hot water thanks to heat recovery.

Benefits

  • Cooling that saves you money, even in electricity use. Gas absorption chillers, HFC-free, which guarantee operational continuity and reduced maintenance as they do not use compressors.
  • Cooling with negligible electricity use.
  • Natural Gas or Propane.
  • Single phase. Only 0.75 kW electric consumption for a 5 TON modular chiller.
  • Real savings: electricity -86%. Drastic reduction of electric demand charge (less than 0.75 kW electric consumption) and no need for big and expensive back-up generators.
  • Natural refrigerant: ODP = 0 | GWP = 0 | HFC and PFAS free.

Applications

  • Ideal for hotels, wellness and sports centres.
  • Can be used in post-heating circuits connected to air handling units.

Technical table

Cooling Mode

Cooling capacity nominal kBtu/h 60,5 (1)
kW 17,7
Gas input (HHV) nominal kBtu/h 94,9
kW 27,8
COP/GUE nominal % 64
Cold water outlet temperature minimum °F 37,4
°C 3
Cold water inlet temperature maximum °F 113
°C 45
Ambient operating temperature maximum °F 120
°C 49
Ambient operating temperature minimum °F 32
°C 0

 

Operating Recovery Circuit

Cooling capacity with heat recovery nominal kBtu/h 61,2 (2)
kW 17,9
Recovery unit heat capacity nominal kBtu/h 86,4 (3)
kW 25,3
COP/GUE nominal (cooling+recovery) % 155
Hot water flow rate (ΔT = 10 °C | 19 °F) maximum GPM 11
m3/h 2,5
minimum GPM 0
m3/h 0
nominal GPM 9,6
m3/h 2,2
Internal recovery circuit pressure drop at nominal water flow Feet of Head 4,34
psig 3
bar 0,2

 

Electrical specifications

Power supply voltage V 208-230
type -- single-phase
frequency Hz 60
Total electrical operating consumption (4) unit only kW 0,75

 

General information

Cooling fluid ammonia R717
water H2O
GWP Global Warming Potential 0
ODP Ozone Depletion Potential 0

 

(1) Cooling capacity at standard conditions of 95 °F | 35 °C ambient temperature. Chilled water outlet temperature 45 °F | 7 °C, inlet 55 °F | 12 °C.
(2) Cooling capacity at standard conditions (with recovery) of 95 °F | 35 °C ambient temperature. Chilled water outlet temperature 45 °F | 7 °C, inlet 55 °F | 12 °C. Heat recovery delivery temperature 122 °F | 50 °C, inlet 104 °F | 40 °C. For conditions other than nominal, apply the correction factors.
(3) Heating capacity at standard conditions (with recovery) of 95 °F | 35 °C ambient temperature. Chilled water outlet temperature 45 °F | 7 °C, inlet 55 °F | 12 °C. Heat recovery delivery temperature 122 °F | 50 °C, inlet 104 °F | 40 °C. For conditions other than nominal, apply the correction factors.
(4) ±10% according to the power supply voltage and tolerance on electrical motors consumption. Measured at outdoor temperature of 86 °F | 30 °C.

Controllers

DDC

DDC

Robur Box 200

Robur Box 200

Robur Box 100

Robur Box 100

Comfort Controller Interface (CCI) panel

Comfort Controller Interface (CCI) panel

Literature